Robots in Hazardous Areas: What the Certificate Register Shows, and What to Settle Before You Specify One

Explosive atmospheres are not limited to refineries. Flour, wood dust, milk powder, solvent vapor and the hydrogen released by battery charging create classified areas in quite ordinary plants. As robots move into those plants, more automation projects run into a zone. This article looks at where those areas tend to be, what the international register of certified robots actually contains, and the five questions a plant should settle before a robot goes in.

 

Where explosive atmospheres hide

Ask a refinery whether it has hazardous areas and the answer is yes. Ask a bakery, a feed mill, a joinery or a wastewater plant and there is often a pause. Yet flour, grain dust, wood dust, sugar, milk powder, solvents, methane and hydrogen can all form explosive atmospheres, and regulators treat them that way. In the EU, directive 1999/92/EC requires employers to classify such places into zones, the UK does the same under DSEAR, and in the US OSHA runs a National Emphasis Program on combustible dust that covers industries from grain and food to wood products, chemicals and metals.

Most of these sites are not hazardous from wall to wall. The explosive atmosphere forms in specific places, and those places follow a pattern:

  • Inside equipment. Dust collectors, filters, silos, bucket elevators, mills, dryers, digesters and covered tanks. The material is concentrated and enclosed, which is exactly what an explosive mixture needs. In many dust-handling plants the most hazardous place is inside the filter, not on the production floor.
  • At transfer points. Filling, emptying, bagging, tipping, pumping and conveying. Wherever material moves from one container to another, some of it escapes as dust or vapor.
  • Where the process creates it. Spraying creates mist and vapor, sanding and grinding create dust, shredding releases whatever was left inside the waste, and charging lead-acid batteries releases hydrogen.
  • When the routine changes. Cleaning, maintenance, opening a normally closed system, tank entry or a process upset. Precautions are designed around normal operation, so non-routine work deserves separate attention.

For a robotics project this matters because the working envelope of the robot often sits exactly at one of these places: palletizing bagged flour at the end of a line, sanding or spraying a part, tending a mill or working inside a tank. A robot can also create a classified area that did not exist before, for example when it brings spraying or a new extraction system into a hall.

Industry

Substance

Where to look first

Bakeries, flour mills, sugar and confectionery

Flour, sugar, starch

Silos, sifters, mills, dust extraction

Grain storage and animal feed

Grain and feed dust

Bucket elevators, conveyors, intake pits, silos

Dairy and food ingredients

Milk powder, lactose

Spray dryers, bagging, filters

Woodworking and furniture

Wood dust

Extraction ductwork, cyclones, filters, sanding lines

Pharmaceuticals and cosmetics

Ethanol, solvents, powdered excipients

Granulation, drying, coating, solvent stores

Paint shops and coating lines

Solvent vapor, overspray, coating powder

Spray booths, mixing rooms, drying ovens

Wastewater and biogas

Methane, hydrogen sulfide

Inlet works, covered tanks, digesters, gas holders

Any site with forklifts

Hydrogen, LPG

Battery charging areas, LPG storage and refueling

 

Dust deserves extra attention. A small explosion inside a piece of equipment can shake loose dust that has settled on beams, ducts and ledges and ignite it, and that secondary explosion can be much larger than the first. Housekeeping is therefore part of explosion protection. Particle size matters too: a finer product grade or a new supplier can change the risk without anyone touching the process.

 

What the certificate register shows

IECEx is the international certification scheme for equipment in explosive atmospheres, and its online certificate system is public. For the Ramtec Ex Robot Census we went through all 85,102 certificates and 66,914 test reports in the scheme, as of August 2026, and kept every certificate that covers a programmable machine that moves or manipulates on its own. The result is 65 certificates, covering roughly 60 distinct robot models from 27 manufacturers, issued by 18 certification bodies. 62 of the 65 are current.

What those robots are built for is lopsided (figure 1): 42 are painting robots, 16 are inspection robots, 4 are tank cleaning robots and 3 are special systems. Painting is where explosion-proof robotics has the longest history, because spray booths using solvent-based paint are hazardous areas and the process has been automated for decades. 51 of the 65 certificates use pressurization (Ex p) as the main protection concept.

 

Reading the certificates more closely gives four points that matter to a buyer (figure 2):

  • Zone. 58 robots are certified for Zone 1 (equipment protection level Gb) and 6 for Zone 0 (Ga); the Zone 0 robots are all inspection or tank cleaning machines. One certificate has to be read in full for its zone. A Zone 2 site can use Zone 1 equipment, so this is not a limitation, but there is no robot in the register certified for Zone 2 only.
  • Dust. Only 10 of the 65 carry a dust marking (Db, Zone 21), and all ten are painting robots. For a flour mill, a bakery, a feed plant or a woodworking line, which are dust zones, the register contains no robot built for the task.
  • Gas group. 7 of the 65 are certified for gas group IIC, the group that includes hydrogen. The large majority are IIB.
  • Conditions. 47 of the 65 certificate numbers end in X, which means specific conditions of use apply. More on that below.

Collaborative robots are almost absent: the register holds one, a painting cobot from FANUC (certificate IECEx DEK 24.0032X). There is no general-purpose cobot for handling, dispensing or assembly in a zone.

Two caveats. The census covers IECEx only. Robots certified under the European ATEX directive alone are not in it, because ATEX has no public central database, and some robots exist in ATEX-only versions. And a certificate says what a machine may do, not what it costs or how long it takes to obtain one. Still, the picture is clear. For painting and for inspection there is a real choice of certified machines. For palletizing, sanding, dispensing, machine tending or handling in a Zone 2, 21 or 22 area, the register offers little. The practical routes are then a standard robot converted and certified for the zone, or a layout that keeps the robot outside the classified area.

 

Five questions to settle before a robot goes in

None of these are engineering questions about the robot. They are questions about the site, and they decide the route before any supplier is contacted.

  1. Who has classified the area, and to what? Zone classification is the responsibility of the operator, not of the robot supplier: in the EU under directive 1999/92/EC, in the UK under DSEAR, in the US under the NEC and OSHA rules. Ask for the hazardous area classification drawing. If there is none, that assessment comes first, carried out by someone competent in area classification. A brochure that says "ATEX ready" proves nothing; a zone on a drawing and a certificate number do.
  2. Gas, dust or both, and which group and temperature class? Flour, wood, sugar and milk powder are dust zones (Zone 20, 21 and 22). Solvents are gas zones (Zone 0, 1 and 2), mostly in gas group IIA or IIB, while hydrogen sits in IIC. The register shows why this matters: a dust zone or a IIC atmosphere narrows the list of certified robots to a handful. Where dust and vapor occur together, as in some pharmaceutical processes, the assessment has to cover both.
  3. Which equipment category, and which certification route? In the EU, Zone 2 and 22 call for category 3 equipment, for which directive 2014/34/EU lets the manufacturer certify under internal production control. Zone 1 and 21 call for category 2, where a notified body is involved. In IECEx terms these are equipment protection levels Gc and Dc versus Gb and Db. The route has a large effect on documentation, cost and lead time, so settle the zone before you settle the robot.
  4. What do the specific conditions of use say? 47 of the 65 certified robots carry the X suffix. The conditions are printed on the certificate itself and range from the permitted ambient temperature to installation requirements for parts of the system. They are the operator's to comply with, so read them before ordering, not after delivery. A certificate also covers the configuration that was tested: a gripper, a camera or a cable added later needs its own assessment.
  5. Which certification system does your market accept? The EU requires ATEX conformity under 2014/34/EU, the UK has UKEX, the US uses the NEC with Class and Division or Zone designations and certification by a Nationally Recognized Testing Laboratory, and Canada uses the Canadian Electrical Code. IECEx is the international scheme these often build on, but it is not by itself the legal approval in the EU or the US. Equipment certified under one system is not automatically accepted under another, in either direction, so check the marking against the requirement of the site where the robot will actually run.

 

A practical way to start

For each area where a robot is planned, ask three things: what could burn if it were finely divided or evaporated, where can it escape or build up, and what could ignite it there. Where the three answers meet in one place, that place needs a proper assessment under the framework that applies to you. Only then does it make sense to open the register, or to talk to anyone about converting a robot.

 

Bram Renkema works at Ramtec in Ridderkerk, the Netherlands, next to the port of Rotterdam. Ramtec converts standard industrial robots and cobots for ATEX and IECEx zones and maintains the Ramtec Ex Robot Census, a verified list of every IECEx-certified robot (ramtec.eu).

 

 

Featured Product

High speed parcel induction with Plus One Robotics' quick deployment induction system.

High speed parcel induction with Plus One Robotics' quick deployment induction system.

InductOne, powered by PickOne AI vision software, is Plus One Robotics' innovative turnkey dual-arm pre-engineered automated induction cell designed to substantially increase throughput ratesand deliver ROI. InductOne is engineered with a meticulous focus on minimizing footprint and weight to enable deployment in space-constrained areas including mezzanines. Its modular, configurable architecture enables seamless greenfield or brownfield integration without costly structural modifications. This standardized system enables quick deployment and rapid performance gains for high-volume parcel sortation centers and e-commerce fulfillment and distribution centers. This modular approach scales quickly as your requirements for more automation growth.